Enter your keyword

Rat Somatostatin,SS ELISA Kit

Rat Somatostatin,SS ELISA Kit

$402.00

Reagent Quantity Microelisa Stripplate 12well×8strips Standard: 90?mol/L 1×0.5ml Standard Diluent 1×1.5ml HRP-Conjugate Reagent 1×6ml Sample Diluent 1×6ml Chromogen Solution A 1×6ml Chromogen Solution B 1×6ml Stop Solution 1×6ml Wash Solution 1×20ml×30 fold User manual 1 Adhesive Strip 105

Compare

Description

The kit takes out from the refrigeration should be balanced 15-30 minutes in the room temperature, if the coated ELISA plates have not been used up after opening, the plate should be stored in sealed bag.
Washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilution. Washing does not affect the result.
Pipette sample with pipettors each step, and proofread its accuracy frequently, avoids the experimental error. Pipette sample within 5 min, if the number of sample is much, recommend using multichannel pipettor.
If the testing material content is excessively high (The sample OD is higher than the first standard well)?please dilute sample (n-fold).
Adhesive Strip only limits the disposable use to avoid cross-contamination.
The substrate should be preserved evade the light.
Please refer to use instruction strictly. The test result determination must take the microtiter plate reader as a standard.
All samples, washing buffer and each kind of reject should refer to infective material process.
Do not mix reagents with those from other lots.

Reactivity : Rat

Method type : Sandwich ELISA

Minimum Detection Limit :

Detection Range : 

Application : ELISA

Purpose : For the quantitative determination of target substances concentrations.

Research Area : Tags & Cell Markers->Cell Type Markers->Tumor Associated, Signal Transduction->Cytoskeleton / ECM->Cell Adhesion->Cell Adhesion Molecules->Vascular, Signal Transduction->Cytoskeleton / ECM->Cell Adhesion->Cell Adhesion Molecules->Endothelial, Neuroscience->Neurology process->Neural Signal Transduction, Stem Cells->Mesenchymal Stem Cells->Surface Molecules, Cancer->Invasion/microenvironment->ECM->Cell adhesion->Other, Cardiovascular->Atherosclerosis->Vascular Inflammation->Leukocyte recruitment->Cell adhesion molecules, Kits/ Lysates/ Other->Kits->ELISA Kits->ELISA Kits->Adhesion molecules ELISA kits, Kits/ Lysates/ Other->Kits->ELISA Kits->ELISA Kits->Atherosclerotic proteins ELISA kits, Cardiovascular->Angiogenesis->Endothelial Cell Markers

Sample Type : serum, plasma, Urine, tissue samples, cell culture supernates

Plate : Pre-coated,Strips (12 x 8)

Restrictions : For Research Use only

Storage : 2 °C - 8 °C

Storage Comment : Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles

Expiry Date : 12 months

Size : 96T

Uniprot No. :  P60042

Abbreviation : SST

Availability : 3-5 working days

Target Details : The hormone somatostatin has active 14 aa and 28 aa forms that are produced by alternate cleavage of the single preproprotein encoded by this gene. Somatostatin is expressed throughout the body and inhibits the release of numerous secondary hormones by binding to high-affinity G-protein-coupled somatostatin receptors. This hormone is an important regulator of the endocrine system through its interactions with pituitary growth hormone, thyroid stimulating hormone, and most hormones of the gastrointestinal tract. Somatostatin also affects rates of neurotransmission in the central nervous system and proliferation of both normal and tumorigenic cells.

Precision : Intra-assay Precision (Precision within an assay) CV%<15%   Three samples of known concentration were tested twenty times on one plate to assess.   Inter-assay Precision (Precision between assays) CV%<15%   Three samples of known concentration were tested in twenty assays to assess. Linearity : To assess the linearity of the assay, samples were spiked with hig3h concentrations of rat ADP in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.

Recovery : The recovery of rat SS spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range   Serum (n=5) 91 87-96   EDTA plasma (n=4) 98 92-106                              

Typical Data : These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. ng/ml OD1 OD2 Average     1000 0.088 0.090 0.089     500 0.135 0.142 0.139     250 0.227 0.237 0.232     125 0.324 0.341 0.333     62.5 0.583 0.598 0.591     31.25 0.847 0.864 0.856     15.62 1.228 1.235 1.232     0 2.155 2.199 2.177